Professional Off-Grid Sizing Tool

Off Grid Solar Load Calculator

Build your energy budget, size your battery bank, and plan your solar array with real-time calculations. Add appliances, see daily Wh, peak surge, and system losses — all in one dashboard.

Appliance Loads

Add each device that will run on your off-grid system

🔌

No appliances yet

Click "Add Appliance" to start building your load profile.

Quick add common loads

System Parameters

Use December/rainy season value for off-grid reliability

How many cloudy days should the battery cover?

12V (small) / 24V (medium) / 48V (large)

Energy Flow

☀️
Solar
🔋
Battery
⚡
Inverter
🏠
Loads

Your Energy Budget

Daily Consumption

0

Wh/day

Monthly Consumption

0

kWh/month

Peak Running

0

W

Peak Surge

0

W

Battery Bank

0

kWh usable capacity

≈ 0 Ah @ 24V

Sized for 2 days autonomy at 80% depth of discharge.

Solar Array

0

W minimum array size

0

× 400W panels

Assumes 75% system efficiency including wiring, conversion, and temperature losses.

Inverter

0 W

Continuous

0 W

Surge (5s)

Includes 25% headroom for future loads and safe operation.

How Off-Grid Solar Sizing Works

Off-grid solar design starts with your energy budget — the total watt-hours you consume per day. Every appliance contributes: watts × hours × quantity. Once you know your daily Wh, you can size the battery bank for autonomy, the solar array to recharge it, and the inverter to handle peak demand.

⚡

Watts vs Watt-Hours

Watts measure power — how fast energy flows. Watt-hours measure energy — how much total work is done. A 100W device running 10 hours = 1000Wh.

📊

Daily Energy Consumption

Sum of (watts × hours × quantity) for every load. This is the foundation of all off-grid sizing.

📈

Peak Load & Surge

Peak running load = sum of all simultaneous watts. Surge load = startup spike (2–7× running for motors). Inverter must handle both.

🔋

Battery Sizing

Battery kWh = Daily Wh × Autonomy Days ÷ (DoD × Efficiency). Lithium allows 80% DoD; lead-acid only 50%.

☀️

Solar Array Sizing

Array W = Daily Wh ÷ (Peak Sun Hours × System Efficiency). Always use worst-month PSH for year-round reliability.

🔌

Inverter Sizing

Continuous rating = Peak running load × 1.25. Surge rating = Highest startup spike × 1.25. Pure sine wave for sensitive electronics.

System Losses & Assumptions

Off-grid systems are less efficient than grid-tied installations because energy passes through more conversion stages. The calculator uses a 75% overall efficiency factor, which accounts for:

Loss Source Typical Range
Inverter conversion 5–10%
Battery round-trip 10–15% (lead) / 5–8% (lithium)
Wiring / cable 2–5%
Charge controller 5–15% (PWM) / 1–5% (MPPT)
Temperature derating 10–20% (cold climates)

For critical systems, reduce the efficiency factor to 70% or lower. For mild climates with lithium batteries and MPPT controllers, 80% may be achievable.

Key Off-Grid Sizing Principles

  • ▸ Size solar for the worst month (December/rainy season), not the annual average.
  • ▸ Plan for 2–5 days of autonomy. One cloudy day shouldn't trigger a generator.
  • ▸ Add 20–30% headroom to inverter and array specs — loads grow over time.
  • ▸ Use MPPT charge controllers — PWM can waste 20–30% of winter production.
  • ▸ Verify surge capacity for well pumps, refrigerators, and air conditioners.

Frequently Asked Questions

Common questions about off-grid solar sizing

What is the difference between watts and watt-hours?

Watts (W) measure instantaneous power — the rate at which an appliance uses electricity. Watt-hours (Wh) measure energy over time. A 60W bulb running 5 hours uses 300Wh (60 × 5).

Why is peak load important?

Peak load determines minimum inverter size. Running a microwave, kettle, and heater simultaneously must stay within your inverter's continuous rating.

What is surge load?

Surge is the brief spike when motors start — often 2–7× running watts. A 150W fridge might surge to 600W. Your inverter must handle this without shutting down.

How do I size a battery bank?

Battery kWh = Daily Wh × Autonomy Days ÷ (DoD × Efficiency). Lithium allows 80% depth of discharge; lead-acid only 50%.

What system losses should I account for?

Inverter 5–10%, battery 5–15%, wiring 2–5%, charge controller 1–15%, and temperature 10–20%. Total system efficiency is typically 70–80%.

Why size solar for the worst month?

Off-grid must work year-round. December has the lowest peak sun hours. Sizing for annual average means your battery runs flat every winter.

Related Solar & Power Tools

More calculators for off-grid and renewable energy planning

🔋

Solar Battery Backup Time Calculator

Estimate how long your battery bank will power your loads during an outage.

Open tool →
⚡

Inverter Battery Runtime Calculator

Calculate runtime for inverter and battery combinations under different loads.

Open tool →
☀️

Solar Charge Time Calculator

See how long it takes to recharge your battery bank from solar panels.

Open tool →
🔌

Portable Power Station Runtime Calculator

Estimate runtime for camping and emergency power stations.

Open tool →